Plastic Electroplating troubleshooting skills

Electroplating troubleshooting skills (a)


Plating troubleshooting skills (a): find out the location of the fault

I. Jumping over method.

Jumping over method means jumping over the plating process that we suspect in the plating process. For example: we suspect that the light nickel abnormal, then we will jump over the light nickel process. The details are as follows.

Normal plating process: plastic pretreatment - burnt copper - acid copper - semi-bright nickel - light nickel - nickel seal - light chrome.

We use the jumping over method the process becomes: plastic pretreatment - scorched copper - acid copper - semi-bright nickel - nickel seal - light chrome.

Then come back to check for abnormalities so that the location of the fault can be determined.

Through this method, it can be adapted to check the location of the fault in the plastic post-processing (plating), the pre-processing is not adapted.

chrome plating for automotive decorative components


Ⅱ. The method of adjusting the position.

The transfer method means changing the direction of the hanging tool or adjusting the position of the product hanging tool row, or change the direction of the product mounted hanging so as to verify the location of the fault is a simple and practical method. For example

1, the original hook in the cast inside, now reverse it (i.e., hook direction towards the outside).

2, the original first row and the third row, all of them are swapped.

Then come back to check for abnormalities, so as to determine the location of the fault.

Through this method, you can test the false burn, anode abnormalities, filter abnormalities, conductive abnormalities in the general method.

chrome plating on home appliance parts

Ⅲ.the comparison method.

Contrast method is a simple method to compare the potion with the potion that has no fault with the potion that may have a fault. Contrast method requires certain conditions, especially suitable for gantry line, several plating lines of large and medium-sized plating plant, or plating industrial park.

1、Newly matched normal plating solution: especially suitable for plastic pre-treatment abnormality checking.

2、Take another normal production plating solution for comparison, for example, large plating factory A line abnormal, B line normal. In the A line plating normal process to our suspicion of a faulty process, take to the B line to continue plating completed.

Then come back to check whether it is abnormal, so as to determine the location of the fault.

If you can master the above three methods, it will be easy to find out the location of the plating fault.