Water boiling machine test

Water boiling testing machines are widely used in industries such as electroplating plastic shell precision components, which helps to observe the degree of adhesion testing of the plated layer of the electroplated product.

Test Method ":

1. Visually inspect the surface of the plating sample layer to ensure that there are no abnormalities such as scratches, scratches, and peeling.

2. Heat purified water to and maintain it at 80℃±2℃?

3. Completely immerse the test plating sample in hot water, boil it in water for 30 minutes, take it out, let stand at room temperature, and cool it to room temperature

4. Inspect the surface of the plating sample layer for abnormalities and conduct a hundred grid adhesion test

5. After the boiling is completed, the plated sample workpiece needs to be left at room temperature for 120 minutes and then inspected. No irreversible appearance changes (such as wrinkling, foaming, coating peeling, etc.) are allowed. The first prerequisite for the boiling test of the plated sample layer is that there is no problem with the adhesion when conducting the conventional 100-grid adhesion test. Secondly, when conducting related resistance tests such as water boiling resistance, cosmetics resistance test, high and low temperature test, the plated sample also needs to meet the conditions. Otherwise, no matter how good the adhesion treatment agent promotes the adhesion between the paint and the substrate, the adhesion treatment agent cannot change the weather resistance of the plated sample.