Analysis on the characteristics, technology and flow of electroplating wastewater treatment
1, Pollution characteristics of wastewater in the electroplating industry
The quality of wastewater in the electroplating industry is complex, and the wastewater contains heavy metal ions such as chromium, zinc, copper, nickel, and cadmium, as well as highly toxic impurities such as acid, alkali, and cyanide. Wastewater from this industry has the following characteristics:
(1) The composition is complex, and the pollutants can be divided into two categories: inorganic pollutants and organic pollutants.
(2) The variation of water quality is large, the pollutants of each production wastewater are diverse, and the coefficient of variation of CODcr is large.
(3) Wastewater is highly toxic and contains a large amount of heavy metal ions. If it is directly discharged without treatment, it will cause great pollution to the surrounding water.
2, Determination of the process plan
The production sewage of a company mainly comes from the acid and alkali treatment of the plated parts before plating and the rinsing after plating. In addition, a certain amount of waste acid is regularly discharged.
(1) Pretreatment of production wastewater
①Removal of Cr6+
At present, chromium-containing electroplating wastewater is mainly treated by redox-precipitation method
Redox method refers to the use of strong oxidants or strong reducing agents to oxidize or reduce toxic substances in wastewater to non-toxic or low-toxic substances. Hexavalent chromium mainly exists in the form of CrO42- in electroplating wastewater, and in the form of Cr2O72- under acidic conditions, the reduction reaction occurs under the action of ferrous ions, and the reduction reaction is fast. The reduced chromium exists in the form of Cr(OH)3 precipitation under alkaline conditions, and the obtained sludge is a mixed precipitation of trivalent chromium and iron hydroxide. To reduce hexavalent chromium with ferrous sulfate, considering that the reduction reaction is not complete, the amount of ferrous sulfate in actual operation is 2.5-3 times the theoretical calculation amount, so the amount of sludge is large.
The specific process is as follows:
Ferrous sulfate
Electroplating wastewater → reduction reaction → PH neutralization → flocculation and precipitation → discharge up to standard
The basic principle is:
Cr2O72-+6Fe2++14H+=2Cr3++6Fe3++7H2O
Cr3++3OH-=Cr(OH)3↓
It can be seen from the above process that the reduction of hexavalent chromium by ferrous sulfate is carried out under relatively acidic conditions, and at the same time, the amount of sludge produced is large, which also increases the difficulty of sludge disposal.
②, the removal of other metal ions
The Cr6+ in the electroplating wastewater exceeds the national discharge standard, and also contains a large amount of metal ions such as Zn2+, Cu2+, Ni2+, Fe2+, so the method of aeration and oxidation under alkaline conditions can not only make the pH value meet the discharge standard, but also can Effectively remove heavy metal ions in wastewater, the principle is:
2HCl+Ca(OH)2=CaCl2+2H2O
Zn2++2OH-=Zn(OH)2↓
Ni2++2OH-=Ni(OH)2↓
Cu2++2OH-=Cu(OH)2↓
Fe2++e=Fe3+
Fe3++3OH-=Fe(OH)3↓
The pH is first adjusted to overbased. Since zinc ions start to precipitate at PH=6.4, they can be completely precipitated (2.0mg/l) when PH=9.3, and begin to dissolve when PH=10.5, so they are divided into two-stage reactions, and the PH of the first-stage reaction pool must be controlled at 9.5 -10 range.
In the first-order reaction, Fe3+ ions can be completely precipitated when PH=4.1, Cu2+ ions can form basic salt precipitation when PH=5.0, PH=7.2 can be completely precipitated, Cr3+ ions begin to precipitate at PH=4.9, and when PH=6.8 It can be completely precipitated, and it begins to dissolve when PH=12. Since Ni2+ ions start to precipitate at PH=7.7, and can be completely precipitated (1.0mg/l) at PH=10.5, so Ni2+ and Fe2+ cannot be completely precipitated in the first-order reaction, so a second-stage reaction is required. In the second-stage aeration oxidation reaction , the pH must be controlled within the range of 10.5-11.
(2) Biochemical treatment of production wastewater
After the two-stage precipitation treatment, the PH value and heavy metal ion indicators in the wastewater have been qualified, but because the wastewater contains organic substances such as additives, the CODcr in the wastewater exceeds the standard. It is determined that the CODcr value after two-stage precipitation is about 200mg/l, while the national standard is 100mg/l. Therefore, after the two-stage precipitation pretreatment, the wastewater is treated by aerobic biochemical method to make it meet the national standard.
Electroplating additives are mainly divided into levelers, stress relievers, surfactants, brighteners, auxiliary brighteners, etc., mainly aldehydes, coumarin, saccharin and decomposition products, etc. Most of these substances are biochemical substances. Aerobic biological treatment process is divided into: activated sludge method and biofilm method. Activated sludge method includes SBR and its improved type, AB method, etc.; biofilm method includes contact oxidation method, biological filter, etc. Among them, SBR and its improved type and biological contact oxidation method are currently popular processes for biochemical treatment of sewage in the world.
①, SBR and its improvement
SBR method is the abbreviation of sequential batch activated sludge method.
SBR sewage treatment technology and its improvement are different from traditional sewage treatment technology. It adopts time division operation instead of space division operation, non-steady-state biochemical reaction instead of steady-state biochemical reaction, static ideal precipitation instead of dynamic precipitation, etc. It implements a combination of ordered and intermittent operations in operation. The SBR method is a method in which the activated sludge treatment process is carried out in a single reaction tank, and the unit operation and time of sewage treatment are continuously treated.
The SBR reaction tank is provided with a partition wall, which divides the reaction tank into a pre-reaction zone and a main reaction zone, and the bottom of the wall is connected with holes. The five processes of water inflow, reaction, sedimentation, decanting and idle in each cycle are carried out in the same tank. Compared with other treatment processes, the SBR process greatly simplifies the sewage treatment structure.
a. During the aeration period, because the aeration system supplies oxygen to the reaction tank, the organic pollutants are oxidized and decomposed by microorganisms, and NH3-N is converted into NO3-N by nitrifying bacteria.
b. Stop aeration during the precipitation period to separate the mud and water. At the same time, the microorganisms use the remaining dissolved oxygen in the water for oxidative decomposition. The reaction tank gradually changes from aerobic state to anoxic state, and starts denitrification reaction.
c. After the precipitation in the decanting period, decanting water is carried out to discharge the supernatant, and the water level in the tank gradually drops. At this time, the reaction tank gradually transitions to an anaerobic state and continues denitrification.
d. During the idle period, the water level in the pool rises from the lowest water level to the highest water level during the idle period.
Compared with the traditional activated sludge process, the SBR process and its improvement have the following characteristics:
a. The process is simple, eliminating the need for sedimentation, secondary sedimentation tanks, sludge return and sludge return equipment.
b. The floor area is saved, which is 20%-30% lower than that of the ordinary aeration method.
c. The operation cost is low, the degree of automation control is high, and the management is convenient. The oxygen absorption rate is high, and the operating cost is reduced by 25%.
d. High treatment efficiency, reliable operation stability, strong load impact resistance, and good effluent quality.
e. The effect of denitrification and dephosphorization is good.
f. The sludge settleability is good.
②, biological contact oxidation method
The biological contact oxidation method is a biofilm method between the activated sludge method and the biological filter. There is a filler in the contact oxidation tank, some microorganisms are fixed and grown on the surface of the filler in the form of biofilm, and some are flocculent suspended growth in water. At this stage, the biological contact oxidation method is to set fillers in the pool, immerse the oxygenated sewage into all the fillers, and flow through the fillers at a certain speed. The filler is covered with biofilm, and there is also a certain amount of activated sludge in the sewage. The sewage is in contact with the biofilm and the activated sludge. Under the action of microorganisms, the sewage is purified. It can be said that the biological contact oxidation method is a biological treatment method between the activated sludge method and the biofilm method, and has the dual effects of activated sludge and biofilm.
The biological contact oxidation process has the following characteristics:
a. The volume of the biological contact oxidation method is high, the equipment of the same size and volume, the processing time is short, the processing capacity is high, and the floor space is saved, which is less than the ordinary aeration method.
b. The operation cost is low, the degree of automation control is high, and the management is convenient. The oxygen absorption rate is high, and no additional agents are required.
c. High treatment efficiency, good and stable effluent quality, under the impact of poison and PH value, the biofilm is less affected and recovers quickly.
d. The operation is stable and reliable, and the load impact resistance is strong.
e. It can effectively prevent sludge bulking, and can give full play to its characteristics of high decomposition and oxidation capacity.
Description of the biological filter process:
The waste acid is regularly discharged into the waste acid tank. After the comprehensive electroplating wastewater and waste acid enter the regulating tank, they are lifted by the pump into the reduction tank, and the reducing agent is added by the dosing pump to reduce the hexavalent chromium to trivalent chromium under acidic conditions. After the reaction, it is retained into the reaction tank, and the dosing pump adds alkali to react, and most of the divalent iron ions, trivalent iron ions, trivalent chromium ions, zinc ions, nickel ions, and copper ions in the wastewater are precipitated under alkaline conditions. , The reacted wastewater enters the 1# sedimentation tank through the guide tube for precipitation and separation.
The supernatant liquid flows into the aeration oxidation tank, and further aeration oxidation, so that the remaining ferrous ions are oxidized to ferric ions, and ferric hydroxide precipitates are formed under alkaline conditions, and precipitation and separation are carried out in the 2# sedimentation tank. After pH adjustment, the supernatant liquid is contacted with oxidation biochemical tank to remove CODcr and then enters the 3# sedimentation tank. The supernatant liquid flows into the clean water tank and discharges up to the standard.
The sludge from each sedimentation tank enters the sludge thickening tank for concentration, and the concentrated sludge is injected into the filter press by the high-pressure pump for filtration. After drying, the sludge is treated as hazardous waste and sent to the solid waste center for disposal.
Processing technology features:
a. Pretreatment of sewage by physical and chemical methods can effectively remove most of the heavy metals in sewage, reduce toxicity, and enhance the biodegradability of sewage.
b. The biochemical treatment adopts the contact oxidation treatment process, which effectively removes CODcr and reduces investment and operating costs.
c. The waste acid adopts the treatment method of "regular discharge and daily treatment", which avoids excessive changes in the water quality of the adjustment tank and affects the subsequent treatment process. The waste acid has high salinity. rise, causing inhibition or even death of activated sludge.
d. Try to adopt the method of gravity self-flow to reduce the power of the pump, choose reliable and efficient brands for dosing, and reduce the consumption of pharmaceuticals. Through the above methods, the operating cost of the sewage treatment system can be greatly reduced.