Oct 09, 2023

Description And Causes Of Coating Defects in Plastic Plating-Electroplating Process (2).

Description and causes of coating defects in plastic plating-Electroplating process (2).

11. Concave coating. The surface of the coating has a dense and irregular cavity (different from the pinhole) showing a "smallpox face" coating. There are two situations where a "smallpox face" coating may be formed.
(1) some units use the glass bead injection method to remove the overflow. When the air pressure of the spray is too high, the kinetic energy inertia of the glass beads will impact the plated surface into small pits. When the coating is thin, without filling the pit, it becomes a "smallpox face" coating.
(2) the metallography of the matrix material alloy is not uniform, and there is selective corrosion in the process of plating pretreatment. The more active metal is first etched to form a pit. If the concave hole is not filled after electroplating, it becomes a "smallpox face" coating.
For example: Ni42Fe substrate, if Ni and Fe are not fully mixed evenly in the metallurgical process, there is likely to be alloy heterogeneity on the surface of the material after rolling. In the pre-plating treatment, because Fe is more active than Ni, it is selectively etched preferentially to form pits. The electroplating layer can not flatten the pit and become a "smallpox face" coating. Similarly, zinc brass also has this phenomenon, if the copper-zinc metallography is uneven, zinc is selectively corroded more selectively than copper before plating, so that the substrate is pits and the coating is pitted after electroplating.
12. Loose dendritic coating. In the dirty plating bath, high concentration of main metal ions, low complexing agent, low additives, too close to the cathode and anode, and too high current density, the loose dendritic coating is easy to be formed in the current zone. The loose coating is like Styrofoam, the dendritic shape is uneven, and the coating can be removed with your fingers.
13. Double-layer coating. The formation of double-layer coating mostly occurs when the working temperature of the bath is relatively high. In the process of electroplating, the workpiece is put out of the bath and hung up again to continue the plating. In this process, if the workpiece is raised for a long time, the plating solution on the workpiece surface precipitates salt frost attached to the workpiece due to water evaporation, and the salt frost does not have time to dissolve during the continuous plating, and the coating is plated on the surface of the salt frost to form a double coating, like a waffle biscuit. A layer of salt frost is sandwiched between the two layers of coating.
To avoid double-layer coating, you can shake the workpiece in the plating solution for a few seconds before continuing plating, let the salt frost dissolve and then be electrified.
14. The coating is black. The main reason for the blackening of the coating is the high metal and organic impurities in the bath, especially in the area of low current density; in the case of insufficient additives, the black coating will also appear in the middle of the large plating area; the temperature is too low and the ion activity is small. When the current is too high, a gray-black coating will be formed. To deal with metal impurities, corrugated plate can be used as cathode and 01-0.2A/dm2 electrolysis. Organic pollution can be treated with 3-5 g / L activated carbon. Use granules and wash them with pure water first.
15. Blunt desquamation. Ni42Fe alloy is easy to be passivated. Pre-plating activation includes two chemical processes, one is oxidation process, the other is oxide dissolution process. If the oxidation process is insufficient or the oxide is not dissolved in time, there is still oxide residue on the plated surface, and the coating will be peeled or rough.
16. Replacement peeling. If there are two different materials on the same workpiece. For example, the surface of the copper substrate is nickel-plated, while copper is exposed on the cut after shearing. When the copper ion in the strong etching tank increases to a limit, the replacement copper layer is easy to be produced on the nickel layer. With replacement copper, tin plating will cause tin layer peeling. In this case, you can only update the strong corrosion solution frequently to avoid replacement peeling.
17. Peeling by oil pollution. If the oil is not removed before plating, there is no coating in the oil-contaminated area during electroplating, even if the coating is covered by false plating, the coating has no binding force with the substrate, and it rises like a rubella block and falls off as soon as it is rubbed.
18. Dark round spot coating. When the workpiece has a larger plating area, such as the heat dissipation block of the pipe. When there are many impurities or insufficient additives in the plating bath, a gray-black dark round spot coating will be formed in the center of the heat dissipation block, like a plaster. Because the center of a large area is a low current region, impurities are concentrated here. Or the bath depth ability decreases when the additive is insufficient.
19. The gloss of the coating is uneven, and the thickness is obviously (visually) uneven. This is due to the fact that the additives have just been added and the additives are not fully dispersed, so that the characteristics of the plating bath are not uniform. After the additives are uniformly dispersed, the fault disappears naturally.
20. The chemical fiber in the plating bath is contaminated, and it can be seen that there is a trace of chemical fiber embedded in the coating. This fault can be overcome by making anode bag PP cloth with soldering iron.