sunxinzheng2008@163.com    +86-13713943531
enLanguage
Cont

Have any Questions?

+86-13713943531

Dec 28, 2021

The latest high-efficiency hard chromium technology

The latest high-efficiency hard chromium technology: double the micro-crack and double the salt spray time

Features


1. The cathode current efficiency is extremely high, up to 25%, saving energy, increasing production capacity, and reducing equipment investment.


2. The current density can be as high as 100 A/Dm.


3. The deposition rate is extremely high, which is more than 40% higher than the traditional hard chromium sulfate process.


4. It does not contain fluoride and will not corrode the low current area of the workpiece.


5. The microhardness of the coating reaches 900-1050HV0.1.


6. The number of micro-cracks in the coating is higher than that of the high-efficiency hard chromium MK550 process, which further significantly improves the corrosion resistance of the coating (relative to the high-efficiency hard chromium MK550 process for the same substrate and the same thickness, the NSS time is extended by 50-100%).


7. The coating is smooth, and the appearance brightness is better than the high-efficiency hard chromium MK550 process.


8. The thickness of the coating is uniform, reducing the excessively thick deposition in the high current area.


9. Will not violently corrode the lead-tin anode, no need to use special anode materials.


10. The pre-treatment process, anode, plating tank, etc. are the same as the general traditional chromium plating process.


Matching Slot


1. Add about one-third of pure water to the pre-cleaned plating tank and heat to 50ºC.


2. Add 250 g/L of chromic acid to the plating tank and stir to completely dissolve it.


3. Add the required high-efficiency, high-corrosion-resistant hard chromium opener MK558M.


4. Add pure water to the required water level and stir evenly.


5. Reheat to 55-60°C.


6. Analyze the concentration of sulfuric acid contained and adjust it to 4.5 g/L.


7. Add an appropriate amount of chromium antifogging agent, such as chromium antifogging agent MK531 (or MK532).


8. Put the electrolytic plate into the plating tank, put the anode plate into the plating tank with electricity, and electrolyze with about 60ASD current for 4-6 hours, after the plating solution reaches the equilibrium state, you can start trial plating.


Rotating cylinder program


1. Change from traditional chromium plating process to MK558 hard chromium plating process: send the plating solution to our company for testing, and it is determined that the total impurities (metal impurities such as copper and iron other than trivalent chromium) are less than 10 g/l, and the chloride ion is not When the amount exceeds 50 mg/L, usually add 40 ml/L of high-efficiency and high corrosion resistance hard chromium opener MK558M, and adjust the sulfate content to the required level to transfer to this hard chromium electroplating process.


2. Change from high-efficiency chromium plating process MK550 to MK558 hard chromium plating process: send the plating solution to our company for testing, and it is determined that the total impurities (metal impurities such as copper and iron other than trivalent chromium) are less than 10 g/l, and the chloride ion is not If it exceeds 50 mg/L, and determine the content of high-efficiency hard chromium catalyst MK550C, usually add 30 ml/L of high-efficiency and corrosion-resistant hard chromium turning agent MK558S, and adjust the sulfate content to the required level to transfer to this hard chromium electroplating process.


Send Inquiry