Sep 07, 2023

Take Feasible Measures To Prevent Solution Running, Dripping And Leakage

Plastic plating-take feasible measures to prevent solution running, dripping and leakage.
Huizhou Boluo Tenglong Technology Co., Ltd. serves you wholeheartedly! Mainly engaged in plastic hydroelectroplating processing, with plastic injection molding processing, mold processing and so on!
The running, running, dripping and leakage of electroplating solution are important pollution sources in electroplating workshop, and great attention should be paid to this aspect, especially the following phenomena should be stopped in time.

t019b646beef490d0c5
(1) strictly prevent the plating bath from being overheated. When the bath is heated too high, the bath will accelerate evaporation and decomposition, and the aerosol contains high concentration of solute. At this time, it will seriously pollute the environment, especially acid and alkali fog, cyanide and chromium fog will have a greater impact on the environment and human harm.
Another disadvantage of overheating electroplating solution is that it may also cause spillover to some solutions, such as chemical or electrochemical deoiling solution and bluing solution. Some of these solutions are covered with a cover that is saponified by soap, while others are covered with inhibitors. These coverings will inhibit the emission of hot water. Once the solution reaches the boiling point, it will suddenly rush out of the liquid surface and spill out of the tank, when Linglan solution will cause loss. If the environment is polluted, industrial accidents may occur as a result. Once t encounters this situation, the consequences are unimaginable. This phenomenon should also be prevented. Before Xiangyuan warms up, clean up the liquid level and remove the suspended matter with fine barbed wire.
In order to avoid the occurrence of the above phenomena, conditional units should be equipped with constant temperature control devices.

t035cb4cf82270a0606
(2) strictly prevent the plating solution from being absorbed by the exhaust fan. When the exhaust fan is improperly equipped (the specification is too large) and the bath level is too high (too close to the edge of the trough), the plating solution is easy to be sucked away, especially before the trough cover is opened, which not only causes environmental pollution, but also causes bath loss. when this happens, timely measures should be taken to solve it, such as reducing the bath level, adjusting the width of the suction port, and setting a liquid collector under the pipe in front of the outdoor exhaust fan. In order to collect inhaled plating bath or condensed water.
(3) reduce the loss of plating bath during large treatment. If no attention is paid to the large-scale treatment of the bath, the loss of the bath is quite large, usually up to 2%-3%, that is, after treatment, the 1000L bath often needs to be supplemented with 20% 30L pure water and corresponding chemical materials. in order to restore to the original liquid level and original concentration, if you can be more careful in operation, mechanical filtration and manual filtration can be combined to filter out the bath as far as possible from the sediment at the bottom of the bath. It can greatly reduce the loss of the plating bath, which can not only save the loss of materials, but also greatly improve the degree of environmental pollution.
The large treatment cycle of the plating bath is inversely proportional to whether the daily maintenance of the plating bath is in place or not. if the plating bath is strengthened before plating and the bath is equipped with a trough cover to avoid the mixing of harmful impurities, the plating bath can be used normally for a long time, and the large treatment frequency can be effectively reduced. the harm to the environment is bound to be greatly reduced.
(4) prevent pollution caused by leakage of plating bath and heating (cooling) pipe. The leakage of electroplating bath or heating (cooling) tube often causes serious pollution, and the causes of leakage vary with manufacturing materials and different kinds of plating, as an example.

t01509cc6ec7b501278
The main contents are as follows: (1) the causes and preventive methods of leakage in the inner lining of lead chromium plating bath. The leakage of the inner lining of the lead chromium plating bath is mainly caused by connecting the anode or too close to the anode, which itself acts as an anode.
The lead chromate formed on its surface is transformed into lead oxide and becomes thinner with the cycle of generation and shedding of lead oxide. when the welding quality is poor or there is trachoma, the leakage takes the lead there, and this kind of leakage is more difficult to find. however, the chromium plating solution seeping out of the lining tank will corrode the iron outer trough, and once the outer tank is corroded, it is possible to drain the whole bath in a short time.
In order to avoid the above phenomena, the following measures can be taken.
Prevention method: a heat-resistant glass or plastic plate is erected on the groove wall near the anode to cut off the contact between the anode plate and the groove lining and reduce the chance of corrosion.
Remedy: drill a small hole in the sound l~1.5mm below the liquid level of the iron outer shell tank, when the inner lining lead groove (including the inner plastic groove) is damaged, the chromium plating solution will be ejected, through this signal you can know that the inner lining groove is damaged and can be repaired immediately, so as to avoid more serious accidents.
(2) the causes and preventive methods of leakage of lead heating (cooling) pipe. The cause of leakage of lead heating (cooling) pipe is similar to that of lead lining tank, but it is also possible to crack due to expansion caused by pressure, and lead pipe leakage is also very harmful to the environment. Once leakage, it is possible to make the solution in the tank out of the tank with steam or water, and if the steam is returned to the boiler, it will be more harmful, and greater accidents may occur when the boiler is destroyed for this reason.
When you find water and steam emitting sound and bubbles at work, you should immediately close the steam and water intake valve and unload the inspection and maintenance to prevent the occurrence of more pollution accidents.
In order to avoid this kind of phenomenon, the return steam and water should not go back into the boiler, but should go into the waste pool, and the quality of lead pipe with required wall thickness should be selected according to the steam pressure.
(3) the causes and preventive methods of leakage in plastic plating bath. The leakage of plastic plating bath is mostly caused by poor welding quality, and the human factors during use are not ruled out.
The plastic trough is prone to aging, and if the selected plastic specification is thin, if the plating part falls into the bottom of the tank, it may be smashed, but it cannot be found at that time, or the party concerned deceives it in order to avoid responsibility, and the result is likely to be completely leaked overnight.
In order to avoid this kind of accident, in addition to adopting the regular plastic welding process, we can also spread a plastic plate at the bottom of the tank, which can play a buffering role in case the plating part falls into the bottom of the tank, thus the possibility of damage to the small plastic plating bath can be realized.

 